Multi-species Mothers Against Decapentaplegic Homolog 1 (Smad1) ELISA Kit
96 Tests
EKU09013
830 €
3 hours
Ice packs
0.132 ng/mL
Colorimetric
0.312-20 ng/mL
6-11 Business days
Developmental science
Double-antibody Sandwich
Short term: 4°C; Long term: see manual.
Mothers Against Decapentaplegic Homolog 1
For research use only. Not for diagnostic procedures.
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat)
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Tissue homogenates, Cell lysates, Cell culture supernates and other biological fluids
Use Multi-species Mothers Against Decapentaplegic Homolog 1 (Smad1) ELISA Kit before 8 months
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
This assay has high sensitivity and excellent specificity for detection of Mothers Against Decapentaplegic Homolog 1
No significant cross-reactivity or interference between Mothers Against Decapentaplegic Homolog 1 and analogues was observed.
No significant cross-reactivity or interference between Mothers Against Decapentaplegic Homolog 1 and analogues was observed.
BSP1, JV4-1, JV41, MADH1, MADR1, SMAD Family Member 1, Mad-related protein 1, Transforming growth factor-beta-signaling protein 1, Mothers against DPP homolog 1
Monoclonals are usually produced in mouse as host species and polyclonals in rabbit or goat. Multi species reactivity is achieved by selecting consensus epitopes when blasting the gene for a reactive, innugenic epitope that is the same in the different target species.
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mothers Against Decapentaplegic Homolog 1 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mothers Against Decapentaplegic Homolog 1 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
© Smad Family 2010-2024. All right reserved. Designed and Developed by GrayGrids.